RUMORED BUZZ ON DP50RB

Rumored Buzz on Dp50rb

Rumored Buzz on Dp50rb

Blog Article

The user is not really allowed to open up the addresses and panel from the process, neither NOTE: system disassemble is authorized. To make sure the program efficiency and basic safety, only Mindray engineers or engineers approved by Mindray can accomplish maintenance.

.. Web site 161 The indicator around the printer Problems manifest in the event the adapter turns orange, as well as the printing printer adapter runs. Disconnect and connect the fails. electricity adapter, ability to the printer adapter once again, and confirm whether the printing is regular just after one minute. Website page 163: Electrical Basic safety Inspection

Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat depth login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.

Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.

The chapter materials the strategy to verify key function and efficiency of product or service. This is often only useful for reference, not preventive execution. Operate checking and testing of this aspect shall be completed by Mindray company engineers and the user jointly. Page 66: Basic Test

Tend not to use any cables apart from the cables provided Using the system by Mindray. three. Make use of the cable supplied with This technique to attach the printer. Other cables may well result in electrical shock. Page fifteen: Mechanical Basic safety

General performance Exam five.5.1 Take a look at Approach Resolution Detection depth Geometric Placement Accuracy Blackout place examination Report the Examination photos five.5.2 Test Information The impression utilized Here's just for reference, stick to the image effect in the actual Take note: situation. Prerequisites: Show: set the contrast and brightness on the scientific application price (or maybe the default position) Procedure natural environment: dark room, simulating the clinical application environment. Web page 76 In affliction the transverse resolution tests targets are horizontally displayed, report the minimum length of two targets which can be clearly regarded. Repeat the operation previously mentioned with the transverse resolution screening targets at other depths. As demonstrated in determine down below. Axial resolution ... Page seventy seven When utilizing the convex probe, continue to keep the transverse resolution testing targets to NOTE: be exhibited close to the midline. When employing a linear probe with steer functionality, do not turn on the steer function when conduct the transverse resolution check. Zoom inside the area exactly where the targets Found if necessary. The diameter in the concentrate on point at a specific Dp50rb login depth is equivalent for the transverse resolution on the depth. Page 78 five.

5.two.3 Geometric positioning accuracy Longitudinal geometric positioning accuracy  Exam Phase: Do adjustments as how in tests the maximum depth. Report the space by 20mm Every section over the longitudinal targets line using the measurement caliper; Decide on the value with the best mistake (to 20mm), calculate the accuracy utilizing the system down below The measurement caliper ought to be positioned for the higher fringe of the goal, Be aware:... Website page 79 Transverse geometric positioning accuracy  Test Action: Include the scan surface area of your phantom with water or few gel, Carefully Make contact with the probe With all the scan floor Adjust the depth, building the transverse targets to become displayed in the graphic. Regulate the main target point to generally be posited beside the transverse targets (the common isn't apparent) Modify parameters like get, TGC, generating Each and every transverse targets to generally be Evidently displayed. Web site eighty 5.five.2.four Blackout Place Test Stage: Go over the scan surface area of the phantom with water or few gel, gently Call the probe With all the scan floor Change the depth in a lessen benefit, and established the focus at the nearest location to the scan floor. Decrease the worth of parameters like AP, Get until finally the qualifications sound just may be witnessed. Web site eighty one: Program Enhance And Routine maintenance

Highest 4 moments tasking for just one transmitted beam, resulting in exceptional time resolution and higher frame price.

Soon after replacing the CPU module, important file should be produced Yet again according to the new MAC address and created into HDD in the device. Or else, the configuration functionality of the product will probably be missing. Just after eliminating the CPU module, Eliminate panhead screws with washers (12 M3X6) mounted on the leading unit box, you will take off the board. Web page 118 Determine eight-29 Disassemble the Control Panel Assembly (one) Maintain the upper edge of control panel assembly, and open up the control panel. Determine 8-thirty Disassemble the User interface Assembly (two) Soon after removing just one countersunk head self-tapping screw PT3X10 fixed over the user interface and just take out the plug of the keyboard and the principle unit connecting cables, you might clear away the control panel assembly.

Page 45 Return “Printer Service” web page, Find the corresponding services through the printer listing and raise the assistance. The procedure integrates motorists of HP printers, after HP printers are connected, drivers might be mounted routinely (about 10s).If auto installation fails, icon will Show on the proper decreased corner of the display screen to warn you that handbook installation is necessary. Webpage forty six: Community Preset

Get a complete and extended watch from the anatomical construction as a result of panoramic imaging coupled with velocity sign and forward/backward scan means generating scanning a lot easier, smoother and even more controllable.

Lower off cable ties connecting the primary device about the Screen by diagonal cutting pliers, and afterwards pull out the corresponding cable plugs.

Content Method Verify the battery periodically : a) Verify if battery may be billed normally when ability-on: That The present capability is a hundred% or ability will increase right after a brief time suggests that the battery can be charged Generally.

Report this page